Select Page
EGR γ sources in resin matrix

EGR γ sources in resin matrix

Radionuclides are incorporated into a thermosetting resin, which is then poured into container.

Our resin sources are sealed sources and are characterized by water equivalent activity, to avoid risks and constraints associated with liquid sources. The radiological characteristics of the sources are measured with calibrated Nal scintillators or HPGe semi-conductors.

Production Range

Catalog References
Custom/On Request
Container
15 ml
50 ml
250 ml
450 ml
500 ml
1000 ml
3000 ml
Any type of container with a volume between 10 ml and 3000 ml.
Activity
5 kBq • 0.14 μCi
18 kBq • 0.5 μCi
37 kBq • 1 μCi
55 kBq • 1.5 μCi
74 kBq • 2 μCi
From 100 Bq to 1 MBq
From 0.003 to 27 μCi
Radionuclide
Ba-133, Cs-137, Eu-152
Mix 12ML01
Cr-51, Mn-54, Co-57, Co-60, Zn-65, Sr-85
Y-88, Cd-109, Sn-113, Cs-134, Cs-137, Ce-139, Am-241 (Non-exhaustive list)

Reference/Product No.

Radionuclide
Water equivalent activity*
k=2 measurement uncertainty*
Reference/Product No.
Eu-152
37000 Bq • 1 μCi
≤ 5%
Eu152 EGR [Type] 15
Ba-133
37000 Bq • 1 μCi
≤ 5%
Ba133 EGR [Type] 15
Cs-137
37000 Bq • 1 μCi
≤ 5%
Cs137 EGR [Type] 15
12ML01*
5000 Bq • 0.14 μCi
18000 Bq • 0.5 μCi
37000 Bq • 1 μCi
55000 Bq • 1.5 μCi
74000 Bq • 2 μCi
[3% ; 6%]
[3% ; 6%]
[3% ; 6%]
[3% ; 6%]
[3% ; 6%]
12ML01 EGR [Type] 05
12ML01 EGR [Type] 10
12ML01 EGR [Type] 15
12ML01 EGR [Type] 20
12ML01 EGR [Type] 30

Standard manufacturing tolerance: ± 30% | IAEA Category: 5 • ISO2919 | Classification: C11111

*Scope N°2-6386 available at www.cofrac.fr or upon request.

** The 12ML01 mixture – Am-241, Cd-109, Ce-139, Co-57, Co-60, Cr-51, Cs-137, Sn-113, Mn-54, Zn-65, Sr-85, Y-88 – generates around 15 peaks over an energy range from 60 keV to 1836 keV. The quantity of each radionuclide is chosen so that the counting rates of the main peak of each radionuclide are the same order of magnitude. See below for additional information on the 12ML01 mixture and on the other mixes available. Other geometries are available on request.

How to compose reference/product no.:

Replace [Type] with the letter E, F, G, H, I, K, L, M or R according to the required geometry. For example: Ba133 EGR E 15

12ML01 Mixture

Composition of the mixture

12ML01 60 keV – 1 836 keV

Radionuclides
Main Rays
% in Activity
Cr-51
320 keV
22.1%
Mn-54
835 keV
5.8%
Co-57
122 keV
137 keV
1.1%
Co-60
1,173 keV
1,333 keV
8.2%
Zn-65
1,116 keV
16.5%
Sr-85
514 keV
3.7%
Y-88
898 keV
1,836 keV
6.9%
Cd-109
88 keV
22.4%
Sn-113
392 keV
4.1%
Cs-137
662 keV
5.6%
Ce-139
166 keV
1.4%
Am-241
60 keV
2.2%

Emission Spectrum

Any other mix of Am-241, Ba-133, Co-60, Cs-137 and Eu-152 can be produced on request for specific activities.

Contact Radnostix

Use the link below to contact us or call 1.208.524.5300