EGS point γ sources
Radionuclides are placed between 2 hot-sealed polyester foils approximately 125 μm thick each, then mounted in a plexiglass ring.
The radiological characteristics of the sources are measured with calibrated Nal scintillators or HPGe semi-conductors.
Production Range
From 0.12 to 2 in
38 mm • 1.5 in
From 1 to 3 in
40 kBq • 1.1 μCi
400 kBq • 11 μCi
700 kBq • 19 μCi
From 0.05 to 27 μCi
Cs-137, Eu-152, Am-241
Mn-54, Sn-113 (Non-exhaustive list)
Kits Available
EGS A sources are also available in kits containing 9 sources of 0.11μCi (4kBq), 1.1μCi (40kBq), 11μCi (400kBq), 19μCi (700kBq) : 241Am, 57Co, 60Co, 51Cr, 137Cs, 54Mn, 22Na, 85Sr, 88Y. Other activities are available on request.
**Due to the short half life of Cr51, Mn54, and Sr85, these sources are only available twice per year in April and November. Orders must be placed no later than February 28 and October 31 in order to receive these sources by these months. Alternatively, those radionuclides may be substituted for others to be available anytime.
Reference/Product No.
40000 Bq • 1.1 μCi
≤ 3.5%
Am241 EGS [Type] 15
40000 Bq • 1.1 μCi
400000 Bq • 11 μCi
≤ 2%
≤ 2%
Ba133 EGS [Type] 15
Ba133 EGS [Type] 20
40000 Bq • 1.1 μCi
400000 Bq • 11 μCi
≤ 1.7%
≤ 1.7%
Co57 EGS [Type] 15
Co57 EGS [Type] 20
40000 Bq • 1.1 μCi
400000 Bq • 11 μCi
≤ 1.5%
≤ 1.5%
Co60 EGS [Type] 15
Co60 EGS [Type] 20
40000 Bq • 1.1 μCi
400000 Bq • 11 μCi
≤ 2%
≤ 2%
Cr51 EGS [Type] 15
Cr51 EGS [Type] 20
40000 Bq • 1.1 μCi
400000 Bq • 11 μCi
≤ 2%
≤ 2%
Cs137 EGS [Type] 15
Cs137 EGS [Type] 20
40000 Bq • 1.1 μCi
≤ 3%
Eu152 EGS [Type] 15
40000 Bq • 1.1 μCi
400000 Bq • 11 μCi
≤ 2%
≤ 2%
Mn54 EGS [Type] 15
Mn54 EGS [Type] 20
40000 Bq • 1.1 μCi
400000 Bq • 11 μCi
≤ 2%
≤ 2%
Na22 EGS [Type] 15
Na22 EGS [Type] 20
40000 Bq • 1.1 μCi
400000 Bq • 11 μCi
≤ 2%
≤ 2%
Sr85 EGS [Type] 15
Sr85 EGS [Type] 20
40000 Bq • 1.1 μCi
400000 Bq • 11 μCi
≤ 2%
≤ 2%
Y88 EGS [Type] 15
Y88 EGS [Type] 20
Standard manufacturing tolerance: ± 30% | IAEA Category: 5 | ISO2919 Classification: C11111
*Scope N°2-6386 available at www.cofrac.fr or upon request.
** The 12ML01 mixture – Am-241, Cd-109, Ce-139, Co-57, Co-60, Cr-51, Cs-137, Sn-113, Mn-54, Zn-65, Sr-85, Y-88 – generates around 15 peaks over an energy range from 60 keV to 1836 keV. The quantity of each radionuclide is chosen so that the counting rates of the main peak of each radionuclide are the same order of magnitude. Other geometries are available on request.
Due to the short half life of several contained radionuclides in the 12ML01 mixture, it is only available twice per year in April and November. Orders must be placed at least one month prior to receive this mixed source by these production months.
See below for additional information on the 12ML01 mixture and on the other mixes available.
*** Recommended use time 5 years for EGSA/E20 geometry (400kBq), only for radionuclides: 241Am and 152Eu.
How to compose reference/product no.:
Replace [Type] with the letter A or E according to the required geometry. For example: Am241 EGS A 20
12ML01 Mixture
Composition of the mixture
12ML01 60 keV – 1 836 keV
137 keV
1,333 keV
1,836 keV
Emission Spectrum
Any other mix of Am-241, Ba-133, Co-60, Cs-137 and Eu-152 can be produced on request for specific activities.
Contact Radnostix
Use the link below to contact us or call 1.208.524.5300